    Installation instructions for thermador char glo ® outdoor barbecues models: cgb30czlp • cgb36fzlp cgb48fzlp • cgb48fszlp installer: please leave these instructions with the unit for the owner. Owner: please retain these instructions for future reference. Warning: if the information in this manual i...

  • Page 2: Contents

    Contents section 1: safety information ................................................................. 1 section 2: gas requirements ............................................................ 2 – 3 natural gas requirements ............................................................................

  • Page 3

    Tested in accordance with ansi z21.58 – 1995, ansi z21.58a – 1998 standard for outdoor cooking gas appliances, and can/cga 1.6-m95, can/cga 1.6a-m98 standard for outdoor cooking gas appliances. This unit is for outdoor use only in a well-ventilated area. Not to be used in a building, garage or any o...

  • Page 4

    Natural gas requirements - inlet connection: 1/2" np with 3/8" npt reducer adapter. Supply pressure: 6" to 14" w.C. Manifold pressure: 4" w.C. Gas consumption the total gas consumption of the thermador char glo ® barbecues with all burners on "hi" is as follows: cgb30rfzlp = 52,000 btu/hr cgb36fzlp ...

  • Page 5

    Caution: the appliance must be isolated from the gas supply system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2" psig (3.5kpa). When checking the manifold gas pressure, the inlet pressure to th...

  • Page 6: Caution

    Page 4 installation of electrical supply circuit should be done by a qualified electrician in accordance with local codes and ordinances. In the absence of local codes or ordinances, the supply should be installed in accordance with the national electric code ansi/nfpa no. 70, current issue, or cana...

  • Page 7

    Section 4: unpacking, moving and placing the unit leaving the unit on the pallet, move the unit close to the final installation site. Unpack and remove all accessory items, packing materials and product literature from inside the unit. Verify the gas supply type. If the unit is not compatible with t...

  • Page 8

    10. All models are equipped with a tank gas pressure regulator that is mounted on the lp tank connector. The regulator is set for lp. See figure 6, below. Section 4: unpacking, moving and placing the unit 9. On all models, the bypass jet must be turned counterclockwise with a small flat-bladed screw...

  • Page 9

    Gas and electrical hook-up with the unit located by the gas stubout, connect the gas supply hose to the manual shut-off valve and open valve. Check the connection points at the shut-off valve for any leaks and repair prior to operating the unit. Connect the power supply cord to the electrical supply...

  • Page 10

    All points of connection to the gas supply should be checked for leaks anytime you smell gas. It is also advisable to recheck them periodically. Follow the steps outlined below: a. Make a soap solution of one part liquid detergent and one part water. B. Make sure all controls are in the "off" positi...

  • Page 11

    Notes.

  • Page 12

    5551 mcfadden avenue, huntington beach, ca 92649 • 800/735-4328 eco 16305 • 5040004761 • © 2002 bsh home appliances corp. • litho u. S. A. 10/02 thermador reserves the right to change specifications or design without notice. Some models are certified for use in canada. Thermador is not responsible f...