10. Models CGB36RU, CGB48RU and
CGB48RSBU are equipped with a pressure
regulator that is permanently mounted within
the cart. The regulator is set for natural gas.
For use with propane, it must be converted.
The regulator is located in the left storage
SECTION 5: UNPACKING, MOVING AND PLACING THE UNIT
9. On all models, the bypass jet must be turned clockwise with a small flat-bladed screwdriver until fully
seated to set proper low flow rate. See Figures 4 and 5.
compartment. Using a flat blade screwdriver,
remove the cap on the top of the regulator
and turn the cap over so that the letters LP are
exposed. Make sure the spring in the regulator
remains in position. Reattach the cap to the
regulator. See Figures 6 and 6A, below.