SECTION 5: UNPACKING, MOVING AND PLACING THE UNIT
Leaving the unit on the pallet, move the unit close to the final installation site. Unpack and remove all accessory items, packing
materials and product literature from inside the unit. Verify the gas supply type. If the unit is not compatible with the gas supply,
it will be necessary to convert it for use with the supply. See conversion instructions below.
LOCATING YOUR CHAR GLO
®
BARBECUE
Natural Gas to Liquid Propane Conversion
Models CGB36RU, CGB48RU and CGB48RSBU are
manufactured at the factory for use with natural gas, and as
such require conversion for use with an LP gas supply. The
conversion should be done by a qualified technician or your
gas supplier. All orifices required for conversion are provided
with the units. The following steps are necessary to convert
for LP operation -
1.
Make sure that the unit is disconnected from the gas and
electrical supplies.
2.
Remove the grill grates and radiants. Unbolt the main
burners from their attachment at the rear of the burner
box and remove.
3.
Remove the knobs and control panel from the unit.
4.
Locate the main burner orifices. From inside control
panel area, locate the brass elbows that the orifices are
attached to. Use a wrench on the flats of these elbows
to keep them from turning during orifice removal and
installation. Remove the main burner orifices and replace
with the LP orifices supplied (marked 54). Do not over-
tighten orifices. Orifice must extend a minimum of 1/8"
into main burner air shutter with burner installed. Make
sure burner will not disengage from orifice..
5.
From behind the unit, remove the louvered cover on the
infrared rotis burner housing.
6.
Locate the infrared burner orifice and remove. Replace
with the LP orifice supplied (marked 59).
7.
Locate the smoker burner. Slide the orifice out of the
burner and remove. Replace with the LP orifice supplied
(marked 73). Reinstall the orifice into the burner.
8.
On Model CGB48RSBU, convert the side burners for LP
operation as follows:
A.
Remove the grate, burner caps, venturis and burner
bases. See Fig. 3, next page.
B.
Remove the burner orifices. Use a 7mm hex socket
on a 3" ratchet extension and apply a piece of tape
to the socket to hold the orifice in the socket while
removing. See Fig. 3A, next page.
C. Replace with the LP orifices supplied (number 115).
Tighten until snug. See Fig 3B, next page.
D. Reassemble the burner bases and venturis. Reinstall
burner caps and grate.
NOTE: Install the conversion sticker (supplied)
beside the rating label.
C
ONVERSION
K
IT
BY
M
ODEL
Model No.
Orifice Description
Part Number Quantity
Remarks
CGB30RCULP
#46 Orifice Hood, Grill Burner
08-04-082-04
2
To Convert LP To NG
#53 Orifice Hood, Infrared Burner
08-04-082-01
1
Conversion Sticker
08-04-731
1
CGB36RU
#54 Orifice Hood, Grill Burner
08-04-082-05
3
To Convert NG To LP
#59 Orifice Hood, Infrared Burner
08-04-082-02
1
#73 Orifice, Smoker Burner
08-04-066-04
1
Conversion Sticker
20-09-337
1
CGB48RSBU
#54 Orifice Hood, Grill Burner
08-04-082-05
3
To Convert NG To LP
#59 Orifice Hood, Infrared Burner
08-04-082-02
1
#73 Orifice, Smoker Burner
08-04-066-04
1
#56 Orifice, Side Burner
15-10-186
2
Conversion Sticker
20-09-337
1
CGB48RU
#54 0rifice Hood, Grill Burner
08-04-082-05
4
To Convert NG To LP
#59 Orifice Hood, Infrared Burner
08-04-082-02
2
#73 Orifice, Smoker Burner
08-04-066-04
1
Conversion Sticker
20-09-337
1
Tools/Parts Required
Socket Driver-1/4" Drive, 3" minimum extension
3/16" Or 7 mm Socket or Wrench
1/2" Deep Well Socket
1/2" Open Wrench
Phillip Screwdriver
Slotted Screwdriver
Masking Tape