    Installation instructions for thermador char glo ® outdoor barbecues models: cgb30rculp • cgb36ru cgb48ru • cgb48rsbu installer: please leave these instructions with the unit for the owner. Owner: please retain these instructions for future reference. Warning: if the information in this manual is no...

  • Page 2

    Inside front cover.

  • Page 3: Contents

    Contents section 1: safety information ................................................................. 2 section 2: gas requirements ................................................................... 3 natural gas requirements ......................................................... 3 propane ga...

  • Page 4

    Tested in accordance with ansi z21.58 – 1995, ansi z21.58a – 1998 standard for outdoor cooking gas appliances, and can/cga 1.6-m95, can/cga 1.6a-m98 standard for outdoor cooking gas appliances. This unit is for outdoor use only in a well-ventilated area. Not to be used in a building, garage or any o...

  • Page 5

    Natural gas requirements - inlet connection: 1/2" np with 3/8" npt reducer adapter. Supply pressure: 6" to 14" w.C. Manifold pressure: 5" w.C. Propane gas requirements - inlet connection: 1/2" np with 3/8" npt reducer adapter. Supply pressure: 11" to 14" w.C. Manifold pressure: 10" w.C. Gas consumpt...

  • Page 6

    Caution: the appliance must be isolated from the gas supply system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2" psig (3.5kpa). When checking the manifold gas pressure, the inlet pressure to th...

  • Page 7

    Section 3: site preparation built-in installations charglo ® outdoor barbecues overall width model no. Overall dimensions cutout dimensions (shelves up) a b c d e f g cgb30rculp 50- 5 / 8 30 26- 5 / 8 n/a n/a n/a 67 cgb36ru 50- 5 / 8 36 26- 5 / 8 37- 3 / 8 35- 5 / 16 22- 3 / 4 73 cgb48rsbu 50- 5 / 8...

  • Page 8

    Section 3: site preparation to combustible construction - below the cooking surface, combustible construction can be placed adjacent to the unit. Clearance of 3" at the lower left rear of the unit must be maintained to allow adequate routing of the gas and electrical supply lines. Minimum horizontal...

  • Page 9

    Installation of electrical supply circuit should be done by a qualified electrician in accordance with local codes and ordinances. In the absence of local codes or ordinances, the supply should be installed in accordance with the national electric code ansi/nfpa no. 70, current issue, or canadian el...

  • Page 10

    Section 5: unpacking, moving and placing the unit leaving the unit on the pallet, move the unit close to the final installation site. Unpack and remove all accessory items, packing materials and product literature from inside the unit. Verify the gas supply type. If the unit is not compatible with t...

  • Page 11

    10. Models cgb36ru, cgb48ru and cgb48rsbu are equipped with a pressure regulator that is permanently mounted within the cart. The regulator is set for natural gas. For use with propane, it must be converted. The regulator is located in the left storage section 5: unpacking, moving and placing the un...

  • Page 12

    11. If models cgb36ru, cgb48ru or cgb48rsbu will be used with an lp cylinder, follow these steps: a. Disconnect the existing flexible gas hose from the regulator and remove hose. B. The proper lp hose and regulator assembly must be provided. Accessory model lphose is available at your thermador deal...

  • Page 13

    If the unit will be freestanding, accessory panel kits are available. Install the side panels, side shelves and rear panel per the instructions provided in the kit. Gas flow based on the input rating of the unit (refer to gas consumption in section 2). • the regulator must be aga certified for use w...

  • Page 14

    All points of connection to the gas supply should be checked for leaks at time of installation or anytime you smell gas. It is also advisable to recheck them periodically. Follow the steps outlined below: a. Make a soap solution of one part liquid detergent and one part water. B. Make sure all contr...

  • Page 15

    Inside back cover.

  • Page 16

    5551 mcfadden avenue, huntington beach, ca 92649 • 800/735-4328 eco 14028 • 08-04-351c • © bsh home appliances corp. 2001 • litho u. S. A. 4/01 specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Cons...