Thermador C271 Service Manual - Convection Roast Mode
Convection Roast Mode
Sequence Of Events;
1)
K4, K8, K10, K11 relays close.
2)
K4 relay energizes both cooling motors; airflow from cooling motor
closes the “air switch” contacts. The completed “air switch” circuit signals
the board {signal voltage). Note if the air switch circuit is not completed
within 40 seconds, the board will interpret a cooling fan fault and display
an F34 ERROR CODE FOR THE UPPER OVEN, AND AN F64 error code
for the lower oven.
3)
K11 relay closes and activates the convection motor. Note: the convection
motor will stop when the oven door is opened during any convection
mode.
4)
Pin header P14 on the relay board sends 24VDC to the double line break
relay (DLB) coil when the coil is energized; the DLB contacts close.
Current flows from L1 to one leg of the bake, broil, and convection
elements.
5)
Bake relay K8 and convection relay K10 alternately open and close and
send current from L2 to the other leg of the bake and convection elements.
The bake element is on for 30 seconds, and the convection element is on
for 30 seconds during each 1-minute cycle.
Page 75