Raritan Dominion KX III Quick Setup Manual - page 6
Dominion KX III Quick Setup Guide
6
QSG-DKX3-v3.5.0-0J-E 255-62-0003-00-RoHS
Select Device Settings > Port Configuration, then click the
Port Name of the target server you want to name.
1. Enter a name for the server up to 32 alphanumeric and
special characters. Click OK.
Specify Power Supply Autodetection
KX III provides dual power supplies.
When both power supplies are used, KX III automatically
detects them and notifies you of their status. Additionally,
both the Powerln1 and Powerln2 Auto Detect checkboxes are
automatically selected on the Power Supply Setup page.
If you are using only one power supply, you can enable
automatic detection for only the power supply in use.
When only one power input is connected, the Power LED on
the front of the KX III device is Red when the checkbox is
selected for an unconnected power supply, and Blue when the
checkbox is not selected for an unconnected power supply.
To enable automatic detection for the power supply in
use:
1. Select Device Settings > Power Supply Setup.
Select the Powerln1 Auto Detect option if you are
plugging power input into power supply number one.
(The left-most power supply at the back of the device
when you are facing rear of the device.)
Or
Select the Powerln2 Auto Detect option if you are
plugging power input into power supply number two.
(The right-most power supply at the back of the
device when you are facing rear of the device.)
2. Click OK.
Configure Date/Time Settings
The date and time settings impact SSL certificate validation if
LDAPS is enabled. Configuring the date and time also ensures
your audit logs will be timestamped correctly.
There are two ways to do this:
•
Manually set the date and time.