Provib Tech VS102 User Manual - page 11
VS102 Electronic Vibration Switch
ProvibTech
10
VS102 Maintenance
Order Information
VS102-ABCD-EFGG
A: Alarms***
A = 0: Dual SPDT Relays
A = 1*: Single SPDT Relay
A = 2: Single SPST Triac, NO
A = 3: Dual SPST Triacs, NO
A = 4: Single SPST Triac, NC
A = 5: Dual SPST Triacs, NC
B: Conduit Entries
B = 0*: 3/4” NPT
B = 1: M20×1.5
C: Mounting Plate or Mounting Stud
C = 0*: Mounting Plate PT500-13
C = 1: Mounting Plate PT500-14
C = 2: Mounting Stud 3/4” NPT
C = 3: Mounting Stud M20×1.5
D: Power Supply
D = 0*: 115VAC or 230VAC
D = 1: 24VDC
E: Hazardous Area Approvals
E = 0: CE Mark (With Local Reset)
E = 1: Multiple approvals (With Local Reset):
CSA: Class I, Div 1, Groups B, C, D, T4 &
T6
CERTIFICATE: 2079756
ATEX: II2G,Ex dⅡB+ H
2
T4T6
KAMA 09ATEX0080 X
T4@Ta= -40℃ to +100℃
T6@Ta= -40℃ to +70℃
PCEC: ExdllCT4
CE Mark
E = 2: Multiple approvals (No Local Reset):
CSA: Class l, Div 1, Groups A, B, C, D,
T4 &T6
CERTIFICATE:
2079756
ATEX: II2G,Ex dⅡCT4T6
KAMA 09ATEX0080 X
T4@Ta= -40
to +100
℃
℃
T6@Ta=
-40
to
+70
℃
℃
PCEC: ExdllCT4
CE Mark
E = 3*: CE Mark (No Local Reset)
F: 4-20mA Outputs
F = 0: None
F = 1*: 4-20mA
GG: Full Scale
GG = 09: 0 - 5.0g pk
GG = 10: 0 - 10.0g pk
GG = 11: 0 - 20.0g pk
GG = 20: 0 –12.5mm/s pk
GG = 21: 0 –20mm/s pk
GG = 22: 0 –25mm/s pk
GG = 23: 0 –50mm/s pk
GG = 24: 0 –100mm/s pk
GG = 30: 0 –12.5mm/s rms
GG = 31: 0 –20mm/s rms
GG = 32*: 0 –25mm/s rms
GG = 33: 0 –50mm/s rms
GG = 34: 0 –100mm/s rms
GG = 40: 0 –0.5ips pk
GG = 41: 0 –1.0ips pk
GG = 42: 0 –2.0ips pk
GG = 43: 0 –4.0ips pk
GG = 50: 0 –0.5ips rms
GG = 51: 0 –1.0ips rms
GG = 52: 0 –2.0ips rms
GG = 53: 0 –4.0ips rms
Note:
* Factory default
*** Alarm delays 6s and relay works in
non-energized mode. E=0/E=1 default setting is