Kemppi 350 Operating Manual - page 17
EN
WeldData Delay
Adjustment Range:
1s – 60s,
1s steps.
Factory Setting: 20s.
Defines how long the Weld Data is
displayed after Welding Ends.
Weld Data display is also turned off when
pulse encoder is turned or any button is
pressed.
Display Delay
Adjustment Range:
1 – 20,
1 steps.
Factory Setting: 10
Defines how long time the information is
displayed (like: “Setting Saved” text). This is
not always the exact time.
Pre Gas Time
Pre Gas Time setting:
0.0s – 9.9s – CURVE,
0.1s steps.
Factory Settings: CURVE
CURVE: Pre Gas time is read from the
Welding Curve.
0.0 – 9.9s: User Pre Gas time setting.
Post Gas Time
Post Gas Time setting:
0.0s – 9.9s – CURVE,
0.1s steps.
Factory Settings: CURVE
CURVE: Pre Gas time is read from the
Welding Curve.
0.0 – 9.9s: User Post Gas time setting.
Control
Remote Control
Selection: USER /
PANEL / REMOTE /
GUN.
Factory Settings: USER
This setting affects to Welding panel (PF65
panel) remote control unit selection.
USER: PF65 user can freely select the
Remote control device.
PANEL: PF65 user can not select the remote
device. Selection is locked to PANEL.
REMOTE: Selection is locked to HAND
REMOTE device.
GUN: Selection is locked to GUN REMOTE
device.
RemoteAutoRecog
Remote Auto
Recognition: ON / OFF.
Factory Setting: ON
ON: Remote control units are recognized.
Welding panel (PF65) jumps to PANEL
selection if the selected remote control
unit disappears. If PF65 USER selection is
allowed (see Control).
OFF: Remote control units are not
recognized. Remote device selection
remains unchanged if the selected remote
control unit disappears
MIG CurrentDisp
ON / OFF
Factory Setting: OFF
ON: Display’s amperage (A) preset values
OFF: Display’s wire feed speed m/min.
WFMotorWarnLev
1.5 – 5.0 A
Factory Setting: 3.5A
The alarm level of wire feed motor current.
Check/service wire feed mechanism,
adjustment and gun components.
WF End Step *
ON/OFF
Factory Setting: OFF
ON: The filler wire steps forward at the end
of the welding cycle.
OFF: Filler wire remains static at the end of
the welding cycle.
AutoWireInch
ON/OFF
Factory Setting: ON
Automatic SuperSnake Wire Inch feature.
When ON, the Wire Inch button drives the
filler wire automatically up to SuperSnake.
Gas Guard
ON/OFF
Factory Setting: OFF
Turns the gas guard on and off, provided
that one is installed.
* Enabled only in processes with filler wire.
15
FastM
ig P
ulse 350, 450 / © Kemppi O
y / 1110