Kemppi 350 Operating Manual - page 13
EN
1-Mig
WFSpeed
0.7 – 25 m/min *
0.05 m/min steps when WFSpeed
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
-9 ... +9
Factory setting is 0
( = curve point)
Adjusts the arc voltage of the curve within certain
limits. In other words, it adjusts the length of the arc
within certain limits
FineTuningMax
-9 ... +9
0.5 steps
Set the limit for maximum arc length
FineTuningMin
-9 ... +9
0.5 steps
Set the limit for minimum arc length
Dynamics
-9 ... +9
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Mig
WFSpeed
0.7 – 25 m/min *
0.05 m/min steps when WFSpeed
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
-9 ... +9
Factory setting is 0
( = curve point)
Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.
FineTuningMax
-9 ... +9
0.5 steps
Set the limit for maximum arc length
FineTuningMin
-9 ... +9
0.5 steps
Set the limit for minimum arc length
Dynamics
-9 ... +9
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Current
-10% ... +15%
Factory Setting
is 0%
Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%.
dOuBle Pulse Mig
WFSpeed
0.7 – 25 m/min *
0.05 m/min steps when WFSpeed
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
-9 ... +9
Factory setting is 0
( = curve point)
Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.
FineTuningMax
-9 ... +9
0.5 steps
Set the limit for maximum arc length
FineTuningMin
-9 ... +9
0.5 steps
Set the limit for minimum arc length
Dynamics
-9 ... +9
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Current
-10% ... +15%
Factory setting
is 0%
Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%
DPulseAmp
0.1 – 3.0 m/min
Factory setting is
CURVE
Adjusts the amplitude of the WFSpeed in 0.1 m/min
steps. Value comes from Welding Curve.
DPulseFreq
0.4 – 8.0 Hz
Factory setting is
CURVE
Adjusts the frequency of the double pulse in 0.1 Hz
steps. Value comes from Welding Curve.
11
FastM
ig P
ulse 350, 450 / © Kemppi O
y / 1110