Interlogix TVB-5301 Configuration Manual - page 20
18
TruVision Series 3 IP Camera FW3.1 Configuration Manual
2. Set the HTTP port, RTSP port, HTTPS port, and server port of the camera.
HTTP Port: The default port number is 80. It can be changed to any port
number that is not occupied.
RTSP Port: The default port number is 554. It can be changed to any port
number in the range from 1 to 65535.
HTTPS Port: The default port number is 443. It can be changed to any port
number that is not occupied.
Server Port: The default server port number is 8000. It can be changed to
any port number in the range from 2000 to 65535.
3. Enter the IP address and port if you want to upload the alarm information to
the remote alarm host. Also check the
Notify Alarm Recipient
option in the
normal Linkage of each event page.
4. Click
Save
to save changes.
To define the DDNS parameters:
1. Click
Configuration
>
Network
>
DDNS
.
2. Check
Enable DDNS
to enable this feature.
3. Select the
DDNS Type
. Select one of the follow options: